FHE Swing

Swing entrance for sterile environment

Opening

Automatic or Manual

Leaf

Single or double with seal or hermetic seal option

  • The FAAC FHE Series automatic entrances are designed for hospital applications and for bacterial contamination controlled environments in accordance with the European Regulation EN16005.
  • The range is made up of various hermetically sealed models available with few surface finishing treatments like aluminium and Stainless Steel.
  • A wide range of accessories complete the offer such as lead panels, vision panels and safety sensors.

Item code

Model

Leaf

Free passage width (mm)

Passage height (mm)

105145

FHE-HSA Airtight automatic swing door

single / double

800 ÷ 2500

2000 ÷ 2500

105146

FHE-HSM Airtight manual swing door

single / double

800 ÷ 2500

2000 ÷ 2500

105147

FHE-HHA Airtight automatic swing door

single

800 ÷ 1300

2000 ÷ 2500

105148

FHE-HM Non Airtight manual swing door

single / double

800 ÷ 2500

2000 ÷ 2500

105149

FHE-HA Non Airtight automatic swing door

single / double

800 ÷ 2500

2000 ÷ 2500

Model

FHE Swing

Power supply voltage

220-240 V~ – 50/60 Hz

Max. power

100 W

standby power

3 W

Use frequency

100%

Electric lock power supply voltage

(N.O./N.C.) 24 V / 500 mA max.

Electric motor

Motor powered at 24V

Max. accessories load

1A – 24 V

Dimensions (LxDxH)

530x105x160 mm (length x height x depth)

Weight

10 kg

Operation in case of power cut

Manual push/pull opening – Spring closing

Max. leaf opening angle

100° ÷ 125°

Opening leaf time

4 – 10 s (adjustable)

Closing leaf time

11 ÷ 60 cm/s (1 leaf) – 20 ÷ 120 cm/s (2 leaves)

Partial opening adjustment

10% – 90% of total opening

Pause time

0 – 30 s

Night pause time

0 – 30 s

Encoder

As standard

Protection sensor monitoring (EN16005)

As standard (may be excluded)

Low energy movement (EN16005)

As standard (may be excluded)

Operating ambient temperature

-20°C ÷ +55°C

Protection class

IP 23 (for internal use only)

Compliance with regulations

EN 16005; EN 61000-6-2; EN 61000-6-3